Features
Product Overview
A mini-tower UPS with line interactive topology, the CyberPower PFC Sinewave CP1000PFCLCD provides battery backup, power protection (using sine wave output), and surge protection for desktop computers, workstations, networking devices, and home entertainment systems requiring active PFC power source compatibility. The CP1000PFCLCD uses Automatic Voltage Regulation (AVR) to correct minor power fluctuations without switching to battery power, which extends battery life. AVR is essential in areas where power fluctuations occur frequently.
Battery Backup
Supplies power long enough for equipment to properly shut down when utility power fails. Helps prevent loss of data and minimizes the component stress caused by a hard shutdown.
Surge Protection
Diverts excess voltage away from sensitive electronic equipment during an AC power surge or power spike to prevent damage.
Data Line Protection
Prevents power surges that travel through telephone, coaxial, and Ethernet lines from causing damage to electronics.
Line Interactive Topology
Exists when a line interactive UPS has an autotransformer that regulates low voltages (e.g., brownouts) and over voltages (e.g., spikes) without having to switch to battery.
Automatic Voltage Regulation (AVR)
Provides clean, consistent AC power by automatically increasing (boosting) low voltage without using battery power when incoming utility power experiences minor fluctuations.
Sine Wave Output
Provides power protection to ENERGY STAR® 6.0 systems with Active PFC power supplies.
GreenPower UPS™ Bypass Design
Is a patented design that allows utility power to bypass the UPS transformer, when AC power is stable, which reduces energy consumption, noise, and heat buildup.
Multifunction LCD Panel
Displays immediate, detailed information on the UPS battery and power conditions, alerting users to potential problems before they can affect critical equipment and cause downtime.
Ultra Quiet Design
Minimizes noise during operation for a quieter work environment.
The batteries have been replaced by the manufacturer as part of the re-conditioning process.
Shipping Note: Shipping to Alaska, Hawaii, PO Boxes, and APO addresses is not available for this item
Warranty: CyberPower Warranty
Optional Asurion Protection Plan: To further protect your purchase, you can buy an Asurion protection plan from Amazon here. Review the FAQs for additional information.
Specs
The batteries have been replaced by the manufacturer as part of the re-conditioning process.
Voltage: | 120V |
Frequency: | 60Hz ± 3Hz |
Plug Type: | NEMA 5-15P |
Plug Style: | Right Angle, 45 Degree Offset Right |
Cord Length: | 5' |
VA: | 1,000 |
Watts: | 600 |
Automatic Voltage Regulation: | Yes 12% |
On Battery Voltage: | 120Vac ± 5% |
On Battery Frequency: | 60Hz ± 1% |
On Battery Waveform: | Sine Wave |
Outlet Type: | NEMA 5-15R |
Outlets - Total: | 10 |
Outlets - Battery & Surge Protected: | 5 |
Outlets - Surge-Only Protected: | 5 |
USB Charge Port – Total | None |
Overload Protection: | Internal circuitry limiting / circuit breaker |
Transfer Time: | 4ms |
Runtime at Half Load (min): | 9 |
Runtime at Full Load (min): | 3 |
Battery Type: | Sealed Lead-Acid |
Battery Size: | 12V/9AH |
Battery Quantity: | 1 |
User Replaceable: | Yes |
Typical Recharge Time: | 8 Hours |
Surge Suppression: | 1,030 Joules |
Phone RJ11 / Ethernet RJ45: | 1-In, 1-Out (Combo) |
Coax Protection RG6: | 1-In, 1-Out |
Multifunction LCD Panel: | Displays: Current/Load Level Runtime Battery Level AVR In Use Battery In Use Input Voltage Output Voltage Output Frequency Overload Wiring Fault Silent Mode |
HID Compliant USB Port: | Yes |
Serial Port: | Yes |
LED Indicators: | Power On Wiring Fault |
Audible Alarms: | On Battery Low Battery Overload Fault |
Software: | PowerPanel® Personal Edition |
Form Factor: | Mini-Tower |
Dimensions - W×H×D (in): | 3.9 x 9.7 x 10.4 inches |
Weight (lbs): | 15.9 lbs |
Operating Temperature: | 32 °F to 104 °F / 0 °C to 40 °C |
Operating Humidity: | 0% - 90% non-condensing |
Safety: | UL1778 cUL 107.3 FCC DOC Class B |
Environmental: | RoHS Compliant |
In the box:
- CyberPower CP1000PFCLCD-R PFC Sinewave UPS Series Battery Backup 1000 VA / 600 W
Specs
The batteries have been replaced by the manufacturer as part of the re-conditioning process.
Voltage: | 120V |
Frequency: | 60Hz ± 3Hz |
Plug Type: | NEMA 5-15P |
Plug Style: | Right Angle, 45 Degree Offset Right |
Cord Length: | 5' |
VA: | 1,000 |
Watts: | 600 |
Automatic Voltage Regulation: | Yes 12% |
On Battery Voltage: | 120Vac ± 5% |
On Battery Frequency: | 60Hz ± 1% |
On Battery Waveform: | Sine Wave |
Outlet Type: | NEMA 5-15R |
Outlets - Total: | 10 |
Outlets - Battery & Surge Protected: | 5 |
Outlets - Surge-Only Protected: | 5 |
USB Charge Port – Total | None |
Overload Protection: | Internal circuitry limiting / circuit breaker |
Transfer Time: | 4ms |
Runtime at Half Load (min): | 9 |
Runtime at Full Load (min): | 3 |
Battery Type: | Sealed Lead-Acid |
Battery Size: | 12V/9AH |
Battery Quantity: | 1 |
User Replaceable: | Yes |
Typical Recharge Time: | 8 Hours |
Surge Suppression: | 1,030 Joules |
Phone RJ11 / Ethernet RJ45: | 1-In, 1-Out (Combo) |
Coax Protection RG6: | 1-In, 1-Out |
Multifunction LCD Panel: | Displays: Current/Load Level Runtime Battery Level AVR In Use Battery In Use Input Voltage Output Voltage Output Frequency Overload Wiring Fault Silent Mode |
HID Compliant USB Port: | Yes |
Serial Port: | Yes |
LED Indicators: | Power On Wiring Fault |
Audible Alarms: | On Battery Low Battery Overload Fault |
Software: | PowerPanel® Personal Edition |
Form Factor: | Mini-Tower |
Dimensions - W×H×D (in): | 3.9 x 9.7 x 10.4 inches |
Weight (lbs): | 15.9 lbs |
Operating Temperature: | 32 °F to 104 °F / 0 °C to 40 °C |
Operating Humidity: | 0% - 90% non-condensing |
Safety: | UL1778 cUL 107.3 FCC DOC Class B |
Environmental: | RoHS Compliant |
In the box:
- CyberPower CP1000PFCLCD-R PFC Sinewave UPS Series Battery Backup 1000 VA / 600 W
Sales Stats
- Speed to First Woot:
- 4h 35m 46.336s
Purchaser Experience
Purchaser Seniority
Quantity Breakdown
Percentage of Sales Per Hour
12 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
---|