Features
A mini-tower UPS with line interactive topology, the CyberPower PFC Sinewave CP1500PFCLCD provides battery backup, power protection (using sine wave output), and surge protection for desktop computers, workstations, networking devices, and home entertainment systems requiring active PFC power source compatibility. The CP1500PFCLCD uses Automatic Voltage Regulation (AVR) to correct minor power fluctuations without switching to battery power, which extends battery life. AVR is essential in areas where power fluctuations occur frequently.
Two USB charge ports (1 Amp shared) power portable devices such as mobile phones, MP3 players, and cameras. The CP1500PFCLCD comes with a three-year warranty (including coverage of batteries) and a $500,000 Connected Equipment Guarantee. Operating temperature - (0 – 40 °C).
Features:
- 1500 VA/900 W Capacity
- Automatic Voltage Regulation
- Line Interactive Topology
- Mini-Tower Form Factor
- 2 USB Charge Ports (5 V/1 A Shared)
- 10 NEMA 5-15R Outlets
- NEMA 5-15P Plug with 5ft Power Cord
Sine Wave Output
Power protection for home and office equipment requiring Active PFC power source compatibility.
Automatic Voltage Regulation
Corrects minor power fluctuations without switching to battery power.
USB Charge Ports
Charge and power USB devices such as tablets, smartphone, MP3 players, and mobile accessories (available on select models).
Reliable Power Protection
Safeguard electronic equipment in a variety of environments with battery backup and surge protection from CyberPower.
Shipping Note: Shipping to Alaska and Hawaii is not available for this item. A physical address is required for delivery. No Military or PO Box shipments available.
Warranty: 1 Year Cyber Power
Specs
The batteries have been replaced by the manufacturer as part of the re-conditioning process.
General | |
UPS Topology | Line Interactive |
Energy Saving | GreenPower UPS™ Bypass |
Active PFC Compatible | Yes |
Input | |
Voltage | 90 – 139 VAC |
Frequency | 57 – 63 Hz |
Plug Type | NEMA 5-15P |
Plug Style | Right Angle, 45° Offset Right |
Cord Length | 5 ft |
Adjustable Voltage Range | 78 – 142 VAC |
Output | |
VA | 1,500 VA |
Watts | 900 W |
On Battery Voltage | 120 VAC ± 5% |
On Battery Frequency | 60 Hz ± 1% |
Automatic Voltage Regulation (line mode) | 12% |
On Battery Waveform | Sine Wave |
Outlets – Total | 10 |
Outlets – Battery & Surge Protected | 5 |
Outlets – Surge-Only Protected | 5 |
Overload Protection | Internal Circuitry Limiting |
Circuit Breaker | |
Transfer Time | 4 ms |
USB Charge | Yes – Two (2) USB 5V/1A charging ports |
Battery | |
Runtime at Half Load | 11 minutes |
Runtime at Full Load | 2 minutes |
Battery Type | Sealed Lead-Acid |
Battery Size | 12V/8.5Ah |
Battery Quantity | 0:00 |
Hot-Swappable | No |
User Replaceable | Yes |
Replacement Battery Cartridge | RB1280X2B |
Replacement Battery Cartridge Quantity | 1 |
Typical Recharge Time | 8 hours |
Surge Protection & Filtering | |
Surge Suppression | 1,030 J |
EMI/RFI Filteration | Yes |
Coax Protection RG6 | 1-In, 1-Out |
Phone RJ11 / Ethernet RJ45 | 1-In, 1-Out (Combo) |
Management & Communications | |
HID Compliant USB Port | Yes |
Serial Port | Yes |
LED Indicators | Power On |
Wiring Fault | |
Audible Alarms | On Battery |
Low Battery | |
Overload | |
Fault | |
Software | PowerPanel® Personal |
Multifunction LCD Panel | Toggle Status Display includes: |
Current/Load Level | |
Runtime | |
Battery Level | |
AVR In Use | |
Battery In Use | |
Input Voltage | |
Output Voltage | |
Output Frequency | |
Overload | |
Wiring Fault | |
Silent Mode | |
Management Cable | USB Cable |
Emergency Power Off (EPO) Port | No |
Physical | |
Form Factor | Mini-Tower |
Dimensions – W×H×D (in) | 3.9 × 10.4 × 14.2 inches |
Weight (lbs) | 24.7 lbs |
Environmental | |
Operating Temperature | 32 – 104 °F (0 – 40 °C) |
Operating Humidity | 0 – 90% (non-condensing) |
Certifications | |
Safety | UL1778 |
cUL 107.3 | |
FCC DOC Class B | |
Environmental | RoHS Compliant |
In the box:
- CyberPower 1500VA/1000W PFC Sinewave UPS
Specs
The batteries have been replaced by the manufacturer as part of the re-conditioning process.
General | |
UPS Topology | Line Interactive |
Energy Saving | GreenPower UPS™ Bypass |
Active PFC Compatible | Yes |
Input | |
Voltage | 90 – 139 VAC |
Frequency | 57 – 63 Hz |
Plug Type | NEMA 5-15P |
Plug Style | Right Angle, 45° Offset Right |
Cord Length | 5 ft |
Adjustable Voltage Range | 78 – 142 VAC |
Output | |
VA | 1,500 VA |
Watts | 900 W |
On Battery Voltage | 120 VAC ± 5% |
On Battery Frequency | 60 Hz ± 1% |
Automatic Voltage Regulation (line mode) | 12% |
On Battery Waveform | Sine Wave |
Outlets – Total | 10 |
Outlets – Battery & Surge Protected | 5 |
Outlets – Surge-Only Protected | 5 |
Overload Protection | Internal Circuitry Limiting |
Circuit Breaker | |
Transfer Time | 4 ms |
USB Charge | Yes – Two (2) USB 5V/1A charging ports |
Battery | |
Runtime at Half Load | 11 minutes |
Runtime at Full Load | 2 minutes |
Battery Type | Sealed Lead-Acid |
Battery Size | 12V/8.5Ah |
Battery Quantity | 0:00 |
Hot-Swappable | No |
User Replaceable | Yes |
Replacement Battery Cartridge | RB1280X2B |
Replacement Battery Cartridge Quantity | 1 |
Typical Recharge Time | 8 hours |
Surge Protection & Filtering | |
Surge Suppression | 1,030 J |
EMI/RFI Filteration | Yes |
Coax Protection RG6 | 1-In, 1-Out |
Phone RJ11 / Ethernet RJ45 | 1-In, 1-Out (Combo) |
Management & Communications | |
HID Compliant USB Port | Yes |
Serial Port | Yes |
LED Indicators | Power On |
Wiring Fault | |
Audible Alarms | On Battery |
Low Battery | |
Overload | |
Fault | |
Software | PowerPanel® Personal |
Multifunction LCD Panel | Toggle Status Display includes: |
Current/Load Level | |
Runtime | |
Battery Level | |
AVR In Use | |
Battery In Use | |
Input Voltage | |
Output Voltage | |
Output Frequency | |
Overload | |
Wiring Fault | |
Silent Mode | |
Management Cable | USB Cable |
Emergency Power Off (EPO) Port | No |
Physical | |
Form Factor | Mini-Tower |
Dimensions – W×H×D (in) | 3.9 × 10.4 × 14.2 inches |
Weight (lbs) | 24.7 lbs |
Environmental | |
Operating Temperature | 32 – 104 °F (0 – 40 °C) |
Operating Humidity | 0 – 90% (non-condensing) |
Certifications | |
Safety | UL1778 |
cUL 107.3 | |
FCC DOC Class B | |
Environmental | RoHS Compliant |
In the box:
- CyberPower 1500VA/1000W PFC Sinewave UPS
Sales Stats
- Speed to First Woot:
- 3h 0m 31.668s
Purchaser Experience
Purchaser Seniority
Quantity Breakdown
Percentage of Sales Per Hour
12 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
---|