Features
Data Line Protection
Prevents power surges that travel through telephone, coaxial, and Ethernet lines from causing damage to electronics.
Surge Protection
Diverts excess voltage away from sensitive electronic equipment during an AC power surge or power spike to prevent damage.
Line Interactive Topology
Exists when a line interactive UPS has an autotransformer that regulates low voltages (e.g., brownouts) and over voltages (e.g., spikes) without having to switch to battery.
Automatic Voltage Regulation (AVR)
Provides clean, consistent AC power by automatically regulating low voltages and over voltages, within defined tolerances, when incoming utility power has minor fluctuations.
Simulated Sine Wave Output
Uses pulse wave modulation to generate a stepped, approximated sine wave to supply cost-effective battery backup power for equipment that does not require sine wave output.
Rack/Tower Versatility
Allows for horizontal rack or vertical tower installation.
LED Status Lights
Indicate Power On, Wiring Fault.
PowerPanel® Business Edition Software
Provides IT professionals with tools for monitoring and managing the UPS and backup power. This software offers remote management functionality. Free software download available.
Shipping Note: Shipping to Alaska and Hawaii is not available for this item. A physical address is required for delivery. No Military or PO Box shipments available.
Warranty: 1 Year Cyber Power
Optional Asurion Protection Plan: To further protect your purchase, you can buy an Asurion protection plan from Amazon here. Review the FAQs for additional information.
Specs
The batteries have been replaced by the manufacturer as part of the re-conditioning process.
- Capacity: 1500 VA / 900 W
- Topology: Line Interactive
- Waveform: Simulated Sine Wave
- Output: 120 VAC ± 10%
- Plug type & cord: NEMA 5-15P, 10 ft. cord
- Outlet types: 8 x NEMA 5-15R
- Communication: USB, Serial, SNMP
In the Box:
- CyberPower CPS1500AVR-R CPS RM/T AVR UPS 1500VA
Specs
The batteries have been replaced by the manufacturer as part of the re-conditioning process.
- Capacity: 1500 VA / 900 W
- Topology: Line Interactive
- Waveform: Simulated Sine Wave
- Output: 120 VAC ± 10%
- Plug type & cord: NEMA 5-15P, 10 ft. cord
- Outlet types: 8 x NEMA 5-15R
- Communication: USB, Serial, SNMP
In the Box:
- CyberPower CPS1500AVR-R CPS RM/T AVR UPS 1500VA