Features
A mini-tower UPS with line interactive topology, the CyberPower CST1500S provides battery backup (using sine wave output) and surge protection for desktop computers, workstations, networking devices, and home entertainment systems requiring active PFC power source compatibility. The CST1500S uses Automatic Voltage Regulation (AVR) to correct minor power fluctuations without switching to battery power, which extends battery life. AVR is essential in areas where power fluctuations occur frequently. Plus, two Type-A USB charge ports power portable devices such as mobile phones and tablets, even during a utility power failure.
Features
- Capacity: 1500 VA / 900 W
- Topology: Line Interactive
- Waveform: Sine Wave
- Plug type & cord: NEMA 5-15P, 5 ft. cord
- Outlets: 10 (5 surge, 5 surge + battery backup)
- Communication: USB, Serial
- Data line protection: Network, Coaxial
- Management software: PowerPanel® Personal
The batteries have been replaced by the manufacturer as part of the re-conditioning process.
Shipping Note: Shipping to Alaska and Hawaii is not available for this item. A physical address is required for delivery. No Military or PO Box shipments available.
Warranty: 1 Year Cyber Power
Optional Asurion Protection Plan: To further protect your purchase, you can buy an Asurion protection plan from Amazon here. Review the FAQs for additional information.
Specs
The batteries have been replaced by the manufacturer as part of the re-conditioning process.
Technical Details
UPS Topology | Line Interactive |
---|---|
Battery Quantity | 2 |
Battery Size | 12 V / 7 Ah |
Battery Type | Sealed Lead-Acid Battery |
Hot Swappable | No |
Runtime at Full Load | 2 min |
Runtime at Half Load | 9 min |
Typical Recharge Time | 8 Hours |
User Replaceable Battery | Yes |
Cord Length | 5 ft (2 m) |
Input Frequency Range | 57 Hz – 63 Hz |
Input Plug Type | NEMA 5-15P |
Input Voltage Range | 90 VAC – 140 VAC |
Nominal Input Voltage | 120 VAC |
Automatic Voltage Regulation | Single Boost |
On Battery Frequency | 60 Hz ± 1% |
On Battery Voltage | 120 VAC ± 5% |
On Battery Waveform | Sine Wave |
Outlet Type | NEMA 5-15R |
Outlets – Battery & Surge Protected | 5 |
Outlets – Surge-Only Protected | 5 |
Outlets – Total | 10 |
Outlets – Widely Spaced | 2 |
Overload Protection | Internal Circuitry Limiting Circuit Breaker Protected |
Typical Transfer Time | 4 ms |
USB Charge Port Amperage | 2.1 Amps (Shared) |
USB Charge Port Quantity | 2 |
VA | 1500 VA |
Watts | 900 W |
EMI/RFI Filtration | Yes |
Network Protection RJ45 | 1-in / 1-Out (10/100/1000) |
Surge Suppression (Joules) | 1030 J |
Audible Alarms | Battery Mode Low Battery Overload Fault |
HID Compliant USB Port | Yes |
LCD | Multifunction LCD |
LED Indicators | Power On Wiring Fault |
Management Cable | USB Cable |
Serial Port | 1 Serial |
Software (Free Download) | PowerPanel® Personal |
Color | Black |
Form Factor | Mini-Tower |
Physical Dimensions – (WxHxD) (cm) | 9.91 x 26.42 x 36.07 (cm) |
Physical Dimensions – (WxHxD) (in) | 3.9 x 10.4 x 14.2 (in) |
Physical Dimensions – (WxHxD) (mm) | 99 x 264 x 361 (mm) |
Weight (kg) | 11.2 |
Weight (lb) | 24.7 |
Operating Elevation | 0 – 10000 ft (0 – 3048 m) |
Operating Relative Humidity | 0 – 90 % (non-condensing) |
Operating Temperature | 32 – 104 °F (0 – 40 °C) |
In the Box:
- (1) CyberPower CST1500S Mini-Tower Battery Back-up | 1500 VA / 900 W | 10 Outlets | 2 USB Charging Ports (Factory Reconditioned)
Specs
The batteries have been replaced by the manufacturer as part of the re-conditioning process.
Technical Details
UPS Topology | Line Interactive |
---|---|
Battery Quantity | 2 |
Battery Size | 12 V / 7 Ah |
Battery Type | Sealed Lead-Acid Battery |
Hot Swappable | No |
Runtime at Full Load | 2 min |
Runtime at Half Load | 9 min |
Typical Recharge Time | 8 Hours |
User Replaceable Battery | Yes |
Cord Length | 5 ft (2 m) |
Input Frequency Range | 57 Hz – 63 Hz |
Input Plug Type | NEMA 5-15P |
Input Voltage Range | 90 VAC – 140 VAC |
Nominal Input Voltage | 120 VAC |
Automatic Voltage Regulation | Single Boost |
On Battery Frequency | 60 Hz ± 1% |
On Battery Voltage | 120 VAC ± 5% |
On Battery Waveform | Sine Wave |
Outlet Type | NEMA 5-15R |
Outlets – Battery & Surge Protected | 5 |
Outlets – Surge-Only Protected | 5 |
Outlets – Total | 10 |
Outlets – Widely Spaced | 2 |
Overload Protection | Internal Circuitry Limiting Circuit Breaker Protected |
Typical Transfer Time | 4 ms |
USB Charge Port Amperage | 2.1 Amps (Shared) |
USB Charge Port Quantity | 2 |
VA | 1500 VA |
Watts | 900 W |
EMI/RFI Filtration | Yes |
Network Protection RJ45 | 1-in / 1-Out (10/100/1000) |
Surge Suppression (Joules) | 1030 J |
Audible Alarms | Battery Mode Low Battery Overload Fault |
HID Compliant USB Port | Yes |
LCD | Multifunction LCD |
LED Indicators | Power On Wiring Fault |
Management Cable | USB Cable |
Serial Port | 1 Serial |
Software (Free Download) | PowerPanel® Personal |
Color | Black |
Form Factor | Mini-Tower |
Physical Dimensions – (WxHxD) (cm) | 9.91 x 26.42 x 36.07 (cm) |
Physical Dimensions – (WxHxD) (in) | 3.9 x 10.4 x 14.2 (in) |
Physical Dimensions – (WxHxD) (mm) | 99 x 264 x 361 (mm) |
Weight (kg) | 11.2 |
Weight (lb) | 24.7 |
Operating Elevation | 0 – 10000 ft (0 – 3048 m) |
Operating Relative Humidity | 0 – 90 % (non-condensing) |
Operating Temperature | 32 – 104 °F (0 – 40 °C) |
In the Box:
- (1) CyberPower CST1500S Mini-Tower Battery Back-up | 1500 VA / 900 W | 10 Outlets | 2 USB Charging Ports (Factory Reconditioned)
Sales Stats
- Speed to First Woot:
- 23m 16.998s
Purchaser Experience
Purchaser Seniority
Quantity Breakdown
Percentage of Sales Per Hour
12 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
---|
Percentage of Sales Per Day
Mon | Tue | Wed | Thu | Fri | Sat | Sun |
---|