Features
- 3000VA/2700W, Double Conversion Online Battery Backup Uninterruptible Power Supply (UPS) System designed to safeguard mission critical servers, applications, and network equipment with isolated power protection
- EBM OPTION: Optional Extended Battery Modules, BP72V60ART2U can be added for expanded runtimes; EXTENDABLE MULTIFUNCTION LCD PANEL: Displays UPS statuses and customizable operating settings up to 10 feet away
- FAST CHARGE TECHNOLOGY: Allows UPS batteries to return to 100 percent capacity more rapidly by utilizing a built in charger inside each Extended Battery Module (EBM; Restores a complete charge within 5 hours regardless of the number of EBMs
- 7 OUTLETS: 6 NEMA 5 20R, 1 NEMA L5 30R BATTERY BACKUP AND SURGE PROTECTED OUTLETS INPUT: 120VAC 30A, Plug Type NEMA L5 30P 10 FT Cord Operating temperature 0 to 40 degree Celsius
The batteries have been replaced by the manufacturer as part of the re-conditioning process. They are new.
Shipping Note: Shipping to Alaska and Hawaii is not available for this item. A physical address is required for delivery. No Military or PO Box shipments available.
Warranty: 1 Year Cyber Power
Optional Asurion Protection Plan: To further protect your purchase, you can buy an Asurion protection plan from Amazon here. Review the FAQs for additional information.
Specs
General | |
---|---|
Energy Saving | ECO Mode Efficiency >95% |
UPS Topology | Online Double Conversion |
Battery | |
Battery Quantity | 6 |
Battery Size | 12 V / 9 Ah |
Battery Type | Sealed Lead-Acid Battery |
Extended Battery Module | BP72V60ART2U |
Hot Swappable | Yes |
Replacement Battery Cartridge | RB1290X6A |
Replacement Battery Cartridge Quantity | 1 |
Runtime at Full Load | 3.5 min |
Runtime at Half Load | 11 min |
Smart Battery Management (SBM) Mode | Yes |
Typical Recharge Time | 4 Hours (0% to 90% charged) |
Input | |
Circuit Breaker | 30 A |
Cold Start | Yes |
Cord Length | 10 ft (3.0 m) |
Input Frequency Range | 40 Hz – 70 Hz |
Input Plug Type | NEMA L5-30P |
Input Power Factor | 0.99 |
Input Voltage Range | 60 VAC – 69 VAC for 0–60% Load 70 VAC – 79 VAC for 0–70% Load 80 VAC – 89 VAC for 0–80% Load 90 VAC – 95 VAC for 0–90% Load |
Nominal Input Voltage | 100 – 125 VAC |
Output | |
Bypass | Internal Bypass (Automatic and Manual) |
Crest Factor | 3:1 |
Harmonic Distortion | < 3% at Linear Load < 5% at Non-Linear Load |
On AC WaveForm | Sine Wave |
On Battery Frequency | 50/60 Hz ± 0.25Hz (auto-sensing or configurable) |
On Battery Voltage | 100/110/115/120/125 VAC ± 2% (configurable) |
On Battery Waveform | Sine Wave |
Outlet Type | 6 – NEMA 5-20R 1 – NEMA L5-30R |
Outlets – Total | 7 |
Output Power Factor | 0.9 |
Overload Protection | Line Mode: 105% ~ 125% Load – 1 min Line Mode: 126% ~ 150% Load – 10 sec Battery Mode: 105% ~ 130% Load – 10 sec Battery Mode: 131% – 150% Load – 2 sec |
Typical Transfer Time | 0 ms |
USB Charge Port | No |
VA | 3000 VA |
VA by Input Type | 3,000 (3.0 kVA) at 120, 125 V input 2,700 (2.7 kVA) at 115, 110 V input 2,400 (2.4 kVA) at 100 V input |
Watts | 2700 W |
Watts by Input Type | 2,700 (2.7 kW) at 120, 125 V input 2,430 (2.4 kW) at 115, 110 V input 2,160 (2.2 kW) at 100 V input |
Surge Protection & Filtering | |
EMI/RFI Filtration | Yes |
Phone / Network Protection RJ11/RJ45 | 1-In / 1-Out (Combo) |
Surge Suppression (Joules) | 1335 J |
Management & Communications | |
Audible Alarms | Battery Mode Low Battery Overload UPS Fault |
Dry Contacts | Yes |
Emergency Power Off (EPO) Port | Yes |
Expansion Slot | Yes – with optional RMCARD305 or RELAYIO500 |
HID Compliant USB Port | Yes |
LCD | Multifunction LCD |
LED Indicators | Power On (White) Line Mode (Green) Battery Mode (Yellow) Bypass Mode (Yellow) Fault (Red) Replace Battery (Red) |
Management Cable | USB Cable |
Removable LCD Control Panel Option | Yes – Requires DB26 cable (not included) |
Rotatable LCD Control Panel Option | Yes |
Serial Port | 1 Serial |
Software (Free Download) | PowerPanel® Business |
Physical | |
Color | Black |
Form Factor | Rack / Tower |
Material of Construction | Metal |
Mounting Hardware | Yes |
Rack Height | 2U |
Dimensions | |
Physical Dimensions – (WxHxD) (cm) | 43.18 x 8.89 x 59.99 (cm) |
Physical Dimensions – (WxHxD) (in) | 17 x 3.5 x 23.62 (in) |
Physical Dimensions – (WxHxD) (mm) | 432 x 89 x 600 (mm) |
Physical Weight (kg) | 30.93 |
Physical Weight (lb) | 68.2 |
In The Box:
- CyberPower OL3000RTXL2U Smart App Online UPS System, 3000VA/2700W, 7 Outlets, 2U Rack/Tower
Specs
General | |
---|---|
Energy Saving | ECO Mode Efficiency >95% |
UPS Topology | Online Double Conversion |
Battery | |
Battery Quantity | 6 |
Battery Size | 12 V / 9 Ah |
Battery Type | Sealed Lead-Acid Battery |
Extended Battery Module | BP72V60ART2U |
Hot Swappable | Yes |
Replacement Battery Cartridge | RB1290X6A |
Replacement Battery Cartridge Quantity | 1 |
Runtime at Full Load | 3.5 min |
Runtime at Half Load | 11 min |
Smart Battery Management (SBM) Mode | Yes |
Typical Recharge Time | 4 Hours (0% to 90% charged) |
Input | |
Circuit Breaker | 30 A |
Cold Start | Yes |
Cord Length | 10 ft (3.0 m) |
Input Frequency Range | 40 Hz – 70 Hz |
Input Plug Type | NEMA L5-30P |
Input Power Factor | 0.99 |
Input Voltage Range | 60 VAC – 69 VAC for 0–60% Load 70 VAC – 79 VAC for 0–70% Load 80 VAC – 89 VAC for 0–80% Load 90 VAC – 95 VAC for 0–90% Load |
Nominal Input Voltage | 100 – 125 VAC |
Output | |
Bypass | Internal Bypass (Automatic and Manual) |
Crest Factor | 3:1 |
Harmonic Distortion | < 3% at Linear Load < 5% at Non-Linear Load |
On AC WaveForm | Sine Wave |
On Battery Frequency | 50/60 Hz ± 0.25Hz (auto-sensing or configurable) |
On Battery Voltage | 100/110/115/120/125 VAC ± 2% (configurable) |
On Battery Waveform | Sine Wave |
Outlet Type | 6 – NEMA 5-20R 1 – NEMA L5-30R |
Outlets – Total | 7 |
Output Power Factor | 0.9 |
Overload Protection | Line Mode: 105% ~ 125% Load – 1 min Line Mode: 126% ~ 150% Load – 10 sec Battery Mode: 105% ~ 130% Load – 10 sec Battery Mode: 131% – 150% Load – 2 sec |
Typical Transfer Time | 0 ms |
USB Charge Port | No |
VA | 3000 VA |
VA by Input Type | 3,000 (3.0 kVA) at 120, 125 V input 2,700 (2.7 kVA) at 115, 110 V input 2,400 (2.4 kVA) at 100 V input |
Watts | 2700 W |
Watts by Input Type | 2,700 (2.7 kW) at 120, 125 V input 2,430 (2.4 kW) at 115, 110 V input 2,160 (2.2 kW) at 100 V input |
Surge Protection & Filtering | |
EMI/RFI Filtration | Yes |
Phone / Network Protection RJ11/RJ45 | 1-In / 1-Out (Combo) |
Surge Suppression (Joules) | 1335 J |
Management & Communications | |
Audible Alarms | Battery Mode Low Battery Overload UPS Fault |
Dry Contacts | Yes |
Emergency Power Off (EPO) Port | Yes |
Expansion Slot | Yes – with optional RMCARD305 or RELAYIO500 |
HID Compliant USB Port | Yes |
LCD | Multifunction LCD |
LED Indicators | Power On (White) Line Mode (Green) Battery Mode (Yellow) Bypass Mode (Yellow) Fault (Red) Replace Battery (Red) |
Management Cable | USB Cable |
Removable LCD Control Panel Option | Yes – Requires DB26 cable (not included) |
Rotatable LCD Control Panel Option | Yes |
Serial Port | 1 Serial |
Software (Free Download) | PowerPanel® Business |
Physical | |
Color | Black |
Form Factor | Rack / Tower |
Material of Construction | Metal |
Mounting Hardware | Yes |
Rack Height | 2U |
Dimensions | |
Physical Dimensions – (WxHxD) (cm) | 43.18 x 8.89 x 59.99 (cm) |
Physical Dimensions – (WxHxD) (in) | 17 x 3.5 x 23.62 (in) |
Physical Dimensions – (WxHxD) (mm) | 432 x 89 x 600 (mm) |
Physical Weight (kg) | 30.93 |
Physical Weight (lb) | 68.2 |
In The Box:
- CyberPower OL3000RTXL2U Smart App Online UPS System, 3000VA/2700W, 7 Outlets, 2U Rack/Tower
Sales Stats
- Speed to First Woot:
- 13h 41m 9.883s
Purchaser Experience
Purchaser Seniority
Quantity Breakdown
Percentage of Sales Per Hour
12 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
---|